People with diabetes need to monitor their blood glucose levels closely in order to optimise their treatment and prevent complications. Self-monitoring of blood glucose levels is a key part of treatment, particularly for insulin-dependent diabetes, but also for all other types of diabetes. To do this, people with diabetes can use blood glucose monitors several times a day to measure the concentration of glucose in their blood. This means they always know how food, exercise and medication affect their blood glucose levels. This can help them to better manage everyday life with diabetes.

How do blood glucose monitors work?

Most blood glucose meters require a drop of capillary blood, which comes from the vessels running directly beneath the skin. This blood contains a particularly high proportion of arterial blood and is therefore ideal for measuring blood glucose levels. To obtain the sample, blood is drawn from the side of the fingertip using a special lancet – a small pricking device. This is then applied to a special test strip, which reacts chemically with the glucose. When the test strip is inserted into the meter, it displays the blood glucose level at the time the blood was taken. The blood glucose level is given in millimoles per litre (mmol/l) or in milligrams per decilitre (mg/dl). In Austria, the second unit is the more commonly used one. To avoid confusion between the units, which could lead to an incorrect calculation of the insulin dose, the metres are calibrated to a single unit. Devices that require blood to measure blood glucose levels operate using one of two different methods. Either the reflectometric (or photometric) method or the electrochemical method is used. The older method is reflectometric blood glucose measurement. This is an optical measurement method. Put simply, the glucose in the blood reacts with enzymes on the test strip, causing a colour change. The meter, into which the test strip is inserted, can detect the intensity of the colour change and use this to calculate the blood glucose level. In electrochemical blood glucose measurement, which is used by many of the newer metres, blood glucose is determined via the electrical conductivity of the blood on the test strip. Here, too, enzymes are used which react with the blood glucose and generate a weak flow of electrons. The stronger the electrical signals, the higher the blood glucose level. During the measurement, care is also taken to ensure that the result is not distorted by medication or other substances, such as vitamins, in the blood.

Tips for taking a reading

    • Wash your hands thoroughly to avoid contaminating the test and skewing the result. Also, use warm water and massage your fingertips to stimulate blood circulation.
    • It is not necessary to disinfect your fingers.
    • As any residual water on your finger would dilute the blood, you must dry your hands thoroughly afterwards. Furthermore, the test strips are very sensitive to moisture and should not be touched with damp hands.
    • Each lancet and each test strip must only be used once. Lancets become blunt quickly and can therefore cause further damage to the skin. Furthermore, repeated use increases the risk of infection.
    • You must prick the skin deep enough with the lancet to obtain a drop of blood. If you have to squeeze your finger tightly to draw blood, this could distort the test result, as tissue fluid may be mixed in.
    • Prick the side of your fingertip. This area is less sensitive to pain.
    • Test on your middle, ring or little finger, as these are used less frequently for grasping than the index finger. If you suffer from sensory disturbances, you can use lancing devices that automatically eject the lancet.
    • Always store the test strips in their sealed packaging and check the expiry date. They can usually be used for six months after the pack has been opened. However, you will find more detailed instructions in the relevant package leaflet.

What is continuous glucose monitoring?

To avoid having to prick your finger constantly and to ensure continuous monitoring of your blood glucose levels, it has been possible for several years now to measure blood glucose levels subcutaneously (under the skin). With this Continuous Glucose Monitoring (CGM), glucose levels in the subcutaneous fatty tissue are measured at short intervals. The aim of this method of glucose monitoring is to improve the control of insulin therapy. These devices consist of two components:

    1. A thread-like sensor, which is inserted into the subcutaneous fat tissue on the abdomen or upper arm using an insertion device. The transmitter is stuck to the skin. The sensor must be replaced at regular intervals – the frequency varies depending on the system used, typically every seven to 14 days.
    2. The second part is a small device that receives, stores and displays the data on a screen.

Measurements are taken every few minutes. This allows any impending hyperglycaemia or hypoglycaemia (high or low blood sugar) to be detected immediately, and the device can sound an alarm. Many CGM devices can also be combined with insulin pumps. With some, both devices can even be operated via a single display. When it comes to continuous glucose monitoring, a distinction is also made between two systems: there is real-time CGM ( abbreviated to rtCGM) and Flash Glucose Monitoring (FGM, also known as Intermittent Scanning CGM, abbreviated to iscCGM), which only displays the current glucose level when it is actively retrieved – for example, via a mobile app. Studies have already shown that rtCGM, when used in combination with conventional blood glucose meters and training, helps to improve HbA1c levels and reduce episodes of hypoglycaemia. The problem with this method of monitoring glucose levels is that the readings in the subcutaneous fatty tissue always lag slightly behind blood glucose levels. There is also a risk of overtreatment.

  • Author

    Gernot Hofer

More on this topic
Hormones

Low testosterone in men: symptoms, causes and treatment

Fatigue, a reduced sex drive, and a lack of energy: these symptoms can have many causes. One possible explanation is a testosterone deficiency. However, it is not possible to determine whether testosterone levels are actually too low based solely on the symptoms or on a single blood test result.

Men's health
Men's health

PSA level: What does it mean, and when is it too high?




The PSA level is one of the best-known laboratory test results relating to the prostate. Many men come across it for the first time during a screening examination or when having symptoms investigated. An abnormal result often raises questions: Is this already a sign of prostate cancer? What levels are considered normal?

Prostate
Pollen allergy

The right diet for hay fever

Anyone suffering from hay fever should pay particular attention to their diet so as not to make the symptoms any worse.

Nutrition
Urology

Prostate health: What men need to know

The prostate is a gland in a man’s body that is only the size of a chestnut, but it plays a crucial role in well-being, urinary function and male sexuality. Benign enlargement and prostate cancer become more common in older age.

Prostate